Prestressed Precast Concrete
Navigation
Types and Durability
Description
Pre-stressed Precast Concrete |
Expected Lifespan
(Years) |
Adjustment Factors |
General | ||
Prestressed precast concrete floor slab complying with CP 81:1999 or BS 8110: Parts 1 and 2 or , cement requirement to ASTM C 150 and aggregate to ASTM 256 or BS 7543.
|
35+ | 1st stage adjustment factor:
In industrial areas (heavy polluted): -15% years. in urban areas: -10% years in suburban areas: -0% years. 2nd stage adjustment factor: Within 20m from expressway: -20% years. Within 20m from major asterial road: -10% years Within 20m from light traffic road: -5% years Within 20m from seawater/ prone to salt spray: -15% years |
Floor slab not complying with BS 8110: Parts 1 and 2 or CP 81:1999. | < 35 |
Combination of adjustment factor (1st stage and 2nd stage) should be added to obtain the durability values. Refer to durability calculator.