Mineral Wool Slab/Batts

Navigation

Maintenance and Cleaning

Description

Mineral wool slabs/ batts

Maintenance Cleaning Cleaning Frequency
Glass fibre to ASTM C726-00a Visual inspection every month for defects (e.g. discoloration or softness caused by water leakage)

Change into a new panel when necessary

Using neutral to mild alkaline cleaner. Avoid acidic and chlorinated products

In accordance to manufacturer’s instructions

Minimum once a year
Rock fibre to ASTM C726-00a Visual inspection every month for defects (e.g. discoloration or softness caused by water leakage)

Change into a new panel when necessary

Using neutral to mild alkaline cleaner. Avoid acidic and chlorinated products

In accordance to manufacturer’s instructions

Minimum once a year
Mineral wool slabs/ batts not to ASTM C726-00a and/ or not designed for proposed use Uninsured In accordance to manufacturer’s instructions Minimum once a year