Waterproofing
Types and Durability
Description
(Floor Waterproofing) |
Expected Lifespan
(Years) |
Adjustment Factors |
Liquid applied system
Liquid (cold/ hot) applied with base material to CP 82: 1999, with method of fixing includes by means of squeegee, roller, brush, trowel or spray, in accordance to manufacturer instruction. Hot applied to ASTM D 6622: 2001 and cold applied to C 898: 2001.
|
10 | Constantly immersed in water or exposed to extreme moisture: – 15% years,
In contact with soil/ ground: -10% years, Partially immersed in water: -5% years. Test certificate from approved local authority: +15% |
Liquid (cold/ hot) applied with base material not in accordance to CP 82: 1999, with method of fixing includes by means of squeegee, roller, brush, trowel or spray, in accordance to manufacturer instruction.
|
< 10 | None |
Integral system*
Integral waterproofing system with method of application includes by means of masonry brush or compressed air-spray equipment, or by dry shake or as admixture, in accordance to manufacturer instruction.
|
10+ | Constantly immersed in water or exposed to extreme moisture: – 15% years,
In contact with soil/ ground: -10% years, Partially immersed in water: -5% years. Test certificate from approved local authority: +15% |
[1]
* to ensure the expected lifespan, integral waterproofing has to be considered in the design state, when the concrete material and mix proportion are determined.
In the case of 2 or more condition of adjustment factor occur, the percentage of year shall be added to obtain the durability value.