Case 1

Navigation

Maintenance and Diagnostics

Regular inspection to monitor the paint performance is encouraged.

Diagnostics of Defect

Visual Inspection

Hardness Test

hardness tester

Hardness Tester can be use to check the compatibility of the paint with the substrate.

Pull Off Test

pull-off tester

Adhesive strengths of paint film on surfaces of concrete or masonry can be ascertained by carrying out a Pull-off Test.

Thermography

thermotracer

Thermography can be used to detect the presence of moisture and its source [7-8].