Mineral Board

Navigation

Types and Durability

Description

Mineral fibreboard

Expected Lifespan

(Years)

Adjustment Factors
Resin bonded mineral wool, factory finished (e.g. with fabric, aluminum foil, glass tissue laminated), approved for particular application 25 Routine access to ceiling void (more than twice/ year: -30% years

Excessive exposure to steam and moisture or under category ‘high humidity‘ to BS8290:Part 2: – 15% years

Near overhead pipe: – 10% years.

Test certificate from approved local testing authority : +15% years

Resin bonded mineral wool, factory finished (e.g. with fabric, aluminum foil, glass tissue laminated). 20
Less than above specification < 20 None

In case of 2 or more conditions of adjustment factor occur, the percentage of year shall be added.

Note: Certain types of board are unsuitable for damp or humid environments. Reference should be made to manufacturer guide.

BS 8290:Part 2 specifies the method for measuring the manufacturing tolerances (dimensional accuracy, squareness and flatness) of tiles, panels, etc. and includes for conditioning under the following environments:

  • Normal: Relative humidity 65 ± 5% at 25 ± 2°C for 36 hours.
  • High humidity: Relative humidity 90 ± 5% at 25 ± 2°C for 24 hours.

BS 8290 provides useful complementary information to this work section:

  • Part 1 deals with design issues generally.
  • Part 2 specifies materials, manufacturing tolerances and strength requirements for suspension grids.
  • Part 3 deals with installation issues. Other sources of information include the Specialist Ceilings and Interiors Association (SCIA) guides and Health Technical Memorandum 60.