Basement Floor Screed
Navigation
Types and Durability
Description
Screed |
Expected Lifespan
(Years ) |
Adjustment Factors |
Cementitious Screed
Direct finished concrete slab to BS 8204: 2000 part 1 & 2. Cements requirement to ASTM C150. |
35+ | Constantly immersed in water or exposed to excessive moisture: -15% years
Addition of water reducing admixture to ASTM C 494: 1999 or BS 5075: Part 1: + 15% years |
Proprietary Screed
Proprietary or preblended polymer modified topping. Thickness and installation in accordance with manufacturer’s recommendation. Includes metallic non-ferrous aggregate and epoxy-reinforced topping. |
25 | Constantly emersed in water or exposed to excessive moisture: -15% years
Addition of water reducing admixture to ASTM C 494: 1999 or BS 5075: Part 1: + 15% years |
Cementitious screed or proprietary screed not to relevant standard or not installed according to manufacturer direction. | < 10 | None |