Case 3
Navigation
- Introduction
- Causes of Defects
- Good Practices
- Standards
- Maintenance and Diagnostics
- Remedial
- Similar Cases
- References
Remedial
![p_fungus](http://maintainability.com.sg/wp-content/uploads/2016/06/p_fungus.jpg)
No major repairs are necessary since it only affects the aesthetics of the facade.
To prevent recurrence [4]:
- remove the source of the dampness and to dry out the walls as thoroughly as possible;
- improve ventilation, if necessary
- remove the infected paint
- sterilise the surface by applying an antiseptic wash and to allow it to dry before redecorating; and
- use a fungi resistant paint