Hydrophobic Coating
Remedial
Upon discovery of damaged coating, the recommended remedial would be to reapply the coating as per the manufacturer’s instruction. Alternatively, it is recommended that the coating is periodically reapplied as per manufacturer instructions to prevent further defects such as biological growth from appearing.
Standards
ISO8251-84 Guidelines for the selection of coating types, tests and methods of assessing the performance of coated aluminium in architectural applications
ISO 19403-6 Paints and varnishes — Wettability — Part 6: Measurement of dynamic contact angle
ASTM D8380 Standard Test Method for Dry Abrasion Resistance of Hydrophobic and Omniphobic Coatings
ASTM F1864 Standard Test Method for Dust Erosion Resistance of Optical and Infrared Transparent Materials and Coatings