GRC

Navigation

Types and Durability

Description

GRC

Expected Lifespan

(Years )

Adjustment Factors
General
Sprayed GRC with factory applied surface coating
30
1st stage adjustment factor:

In industrial areas (heavy polluted): -15% of no. of years

In urban areas: -10% of no. of years

In suburban areas: no adjustment

2nd stage adjustment factor:

Within 20m from express way: -20% of no. of years

Within 20m from major arterial road: -10% of no. of years

Within 20m from light traffic road: -5% of no. of years

Test certificate from approved local testing authority : +15% of no. of years

Sprayed GRC with site applied surface coating
25
Premixed GRC with factory applied surface coating
30
Premixed GRC with site applied surface coating
25
Unclassified, i.e. GRP sheet/section not to BS 4154 Part 1, and/or not UV stabilized, and/or less than 1.83kg/m² weight/1 mm thickness.
Uninsured
.

Combination of adjustment factors (1st stage and 2nd stage) should be added to obtain the durability values. Refer to durability calculator.