Concrete Encased Steel
Navigation
Maintenance and Cleaning
Concrete Encased Steel
|
Maintenance
|
Cleaning
|
Hot rolled steel encased in insitu concrete to BS 8110: Parts land 2, with cover to steel complying with Table 3.3 and specified to match the appropriate exposure category selected from Table 3.2. Minimum nominal cover to all reinforcement of 20mm. Minimum cement content 275kg/m³. |
None
|
None
|
Structural hollow section with the concrete filling to BS 8110: Parts 1 and 2. |
None
|
None
|
Unclassified, ie concrete encased steel beams, concrete encasement not complying with BS 8110: Parts 1 and 2. |
Unclassified
|
Unclassified
|